    ETCR9600 LV Transducer Transformation Ratio Tester Data Storage 3000 Groups

    • Item #: 9SIVSY0KUU9107
    • Mfr. Part #: 9600
    • ETCR9600 LV Transducer Transformation Ratio Tester Data Storage 3000 Groups
    +
    +
    Overview
    Specs
    Reviews
    ETCR9600 LV Transducer Transformation Ratio Tester Data Storage 3000 Groups
    Notice:
    The standard package don't include batteries. Because, the international air shipping forbid to ship liquid, powder and batteries, we can not put them in the package box. Hope you can understand buy them in your local store or supermarket.
    At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
    Thanks for your support!
    Reference Condition
    Influence Quantity Base Condition Working Condition
    Environment Terperature 23? ±5? -15? ~50?
    Environment Humidity 40%~60% <80%
    Sine Wave Distortion =1% =3%
    Signal Frequency 50HZ±5HZ 45HZ~65HZ
    Angel Error Test Primary Current Clamp 60A±1A 0.0A ±800A
    Secondary Current Clamp 1A± 0.2A 10mA~5A
    External Electric & magnetic Field Should avoid
    The tested wire position The tested wire is at the center of the clamp
    Technical Parameter
    Function Description
    Fuction Current, transformation ratio, ratio error, angle error test, phase and polarity adjustment of the low voltage primary and secondary circuit of the current transducer
    Primary Current Clamp Test Accuracy Range: 0.0A ~800A;
    Resolution: 0.1A;
    Accuracy: ± 0.5 %FS( 23? ±3?, below 70% RH, the detected conductor is in the center position of the clamp);
    Secondary Current Clamp Test Accuracy Range: 0.00 mA~5A;
    Resolution: 0.01 mA; Accuracy: ± 0.5 %FS
    Transformation Ratio Measurement Range 1~500
    Transformation Ratio Resolution 0.1
    Angle Error Test Accuracy Range: 0~360°; Accuracy: ±3°
    Automatic Shut Down 15 minutes after boot up, the meter shuts down automatically without any operation
    Battery Specification Alkaline batteries ( 1.5V AAA × 4)
    Battery Voltage When battery voltage is lower than 4.8V, low battery voltage symbol will display and remind to replace battery.
    Overflow Display Exceed measure range overflow function: OLA symbol display
    Sampling Rate 3 times/second
    Data Storage 3000 groups
    Primary Current Clamp Size Jaw Size: f80mm×80mm; Out Shape Size: 76mm×255mm×31mm
    Secondary Current Clamp Size Jaw Size: f8mm; Out Shape Size: 137mm×40mm× 19.5 mm
    Host Dimension 75mm×170mm×30mm
    Current Clamp Cable Length 2M
    Instrument Weight 1000g
    Insulation Strength AC3700V/rms between the core and shell
    Host 1 PCS
    Primary Current Clamp 1 PCS
    Secondary Current Clamp 1 PCS
    Tool bag 1 PCS
    Manual 1 PCS
    Certificate 1 PCS
    Warranty Card 1 PCS

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    Manufacturer Contact Info

    LOADING...