Instructions:Please pay attention to the following points when using the extender:
1. The card reader must be connected to the transmitter, that is, the GND of both should be connected;
2. The access control board must be connected to the receiving converter, that is, the GND of both should be connected;
3. 5/6 type network cable can be used as the signal transmission line; the reader can be powered separately from the access control board 100 meters or more;
4. If the access control board is powered, it is best to supply the remaining pairs of cable in parallel, leaving only one pair of lines for transmitting 485 signals:
5. If you can't receive the signal, please open the converter cover and observe the change of the indicator light: working status: red light is on the sending end: the blue light is on; the receiving end: receiving the signal green light is on;
6. Converter 485 terminal GND can not be connected under normal circumstances, only connect AB two lines, such as using shielded transmission line can be connected to the shielding layer;
7. The extender needs to be used in pairs to function properly. The user should decode the card number when using it alone.