Features Trigger Signal Source: High level trigger ( 3.0V -24V), low level trigger ( 0.0V - 0.2V ), switch control (passive switch)
Output Capability: Control devices within 30V 5A DC or within 220V 5A
AC Quiescent Current: 15mA
Working Current: 50mA
Service Life: More than 100, 000 times
Working Temperature: -40-85
Timing Range: 0.01 seconds (minimum) - 9999 minutes (maximum) continuously adjustable How to Choose the
Timing Range: In the OP/CL parameter modification interface, short press the STOP button to select the timing range; XXXX has no decimal point, and the timing range is 1s - 9999s XXX. X Decimal point in the tenth place, timing range 0.1 s - 999.9 s XX. XX Decimal point is in the hundredth place, timing range 0.01 s - 99.99 s X. X. X. X full decimal point, timing range 1min - 9999min For example, if you want to set the OP to 3.2 seconds, then move the decimal point to the ten, the LCD display 003.2
Parameter Description: OP on time, CL off time, LOP cycle times (1-9999 times, "----" represents infinite cycles)
Operating Mode:
P1: After the signal is triggered, the relay is turned on for the OP time and then turned off; within the OP time, the signal is triggered again invalid
P2: After the signal is triggered, the relay turns on the OP time and then turns off; within the OP time, the signal is triggered again to retime
P3: After the signal is triggered, the relay is turned on for OP time and then disconnected; within OP time, the signal is triggered again to reset, the rela...