Product Overview 5A AC Overcurrent Protection Sensor Module using a current transformer for noncontact AC current detection. When current exceeds the set threshold, the onboard relay is triggered to control external circuits. Ideal for AC load protection and safety control systems.
1.
Product Parameters Sensor Type: AC current transformer + relay Detection
Current Range: AC 0.35
A Working Voltage: DC 5.0
V Working Current: <20 mA Output Type: Relay switch signal Relay Contacts: COM / NO / NC Operating Frequency: 20 Hz400 Hz Threshold Setting: Adjustable potentiometer Max Wire Diameter: 5.2 mm Mounting Hole Diameter: 3 mm Hole Spacing: 52.5 mm Board Size: 38 × 44 mm Operating Temperature: 40 °C to +85 °C
2. Pin Function
Description VCC (IN+): DC power input positive
GND: DC power ground
COM: Relay common terminal
NO: Normally open contact
NC: Normally closed contact
3. Common Questions & Answers (FAQ)
Q1: What type of current can this module detect?
A1: It detects singlephase AC current only.
Q2: How is the overcurrent point set?
A2: By adjusting the onboard potentiometer.
Q3: What happens when overcurrent occurs?
A3: The relay is energized and switches its contacts.
Q4: Is the detection isolated from the load?
A4: Yes, current is sensed via a current transformer.
Q5: Can it directly control external circuits?
A5: Yes, using the relay COM, NO, and NC contacts.