SHOP BY VA Rating

- Model #: SMX2000LV-0
- $2,180.99 –

- Model #: TB00095W91Y
- $146.32 –

- Model #: BEAP9641
- $689.99 –

- Model #: B02H6ZC97
- $359.90 –
![APC SMT1500RM2UCUS Smart-UPS, Line Interactive, 1500VA, Rackmount 2U, 120V, 6x NEMA 5-15R outlets, SmartConnect Port+SmartSlot, AVR, LCD [TAA] - 2U Rack-mountable - AVR - 3 Hour Recharge -120 V Input APC SMT1500RM2UCUS Smart-UPS, Line Interactive, 1500VA, Rackmount 2U, 120V, 6x NEMA 5-15R outlets, SmartConnect Port+SmartSlot, AVR, LCD [TAA] - 2U Rack-mountable - AVR - 3 Hour Recharge -120 V Input](https://c1.neweggimages.com/productimage/nb300/A0ZXD2204040VPCEHAD.jpg)
- Battery Run Time: Run time Half Load (500W): Approximately 23 minutes Full Load (1000W): Approximately 6 minutes
- Brand: APC
- Interface Port: RJ-45, USB, Smart-Slot
- Rackmountable: Yes
- Model #: SMT1500RM2UCUS
- $1,789.99 –
- More options from $1,789.99 - $1,899.99

- Model #: JISU972HF2F
- $147.89 –

- Model #: BH0Q89EW3Z
- $199.90 –

- Model #: BEINTERNET750U
- $158.00 –

- Model #: BHQ08AD5C3V
- $1,799.99 –

- Model #: TB000ARA51C
- $186.89 –

- Brand: APC
- Model #: SMT1000CUS
- $799.99 –
- More options from $799.99 - $999.99

- Model #: BESMX3000LVNC
- $3,699.99 –

- $174.99 –

- Outlets: 6
- Output Frequency: 47 - 63 Hz
- Battery Recharge Time: 8 hour(s)
- Series: Back-UPS CS
- Model #: BK500EI
- $167.01 –
- More options from $141.37 - $167.01

- Outlets: 11
- Output Voltage: 208V, 230V
- Outlet Type: 1 x IEC 320 C19 (Battery Backup) 2 x IEC Jumpers (Battery Backup) 8 x IEC 320 C13 (Battery Backup)
- Model #: SMX2200R2HVNC
- $3,667.70 –
- More options from $3,316.11 - $3,667.70

- Outlets: 7
- Battery Run Time: 4 Minute
- Battery Recharge Time: <8 Hours
- Series: Smart-UPS On-Line
- Model #: SRT10KXLT
- $11,747.55 –

- Model #: BP36V42-3U
- $1,822.45 –

- Output Frequency: 60 Hz
- Brand: APC
- Part Number: SMX2KR2UX145
- VA Rating: 1920 VA
- Model #: SMX2KR2UX145
- $2,151.43 –
- More options from $2,047.99 - $2,151.43

- Outlets: 6 x NEMA 5-15/20R
- Brand: MINUTEMAN
- Input Voltage Range: 0 V AC - 160 V AC
- Output Voltage: 120 V AC
- Model #: EC2000RT2U
- $1,726.62 –

- Parts: 3 Year
- Model #: 5PX2000RT3UNG2
- $2,424.86 –

- Outlets: 1 x NEMA L6-30R 18 x NEMA 5-20R 2 x NEMA L6-20R Hardwired
- Battery Run Time: 0.05 Hour 0.13 Hour
- Input Voltage Range: 100V AC to 276V AC 120V AC Nominal 200V AC Nominal 208V AC Nominal 230V AC Nominal 240V AC Nominal
- Output Voltage: 120V AC Nominal 208V AC Nominal 220V AC Nominal 230V AC Nominal 240V AC Nominal
- Model #: 9PX6KTF5
- $7,483.02 –
- More options from $7,299.99 - $7,483.02

- Outlets: 8
- Output Frequency: 50/60 Hz +/-0.1 % (autosensing)
- Input Frequency: 50/60 Hz
- Input Connection: NEMA 5-15P
- Model #: 5P750
- $494.58 –
- More options from $372.06 - $592.81

- Outlets: 10
- Battery Run Time: 3.4 min Full Load / 10.9 min Half Load
- Brand: MINUTEMAN
- International Version: 120V
- Model #: ETR2000LGU
- $506.74 –
- More options from $499.99 - $506.74
What is an Uninterruptible Power Supply?
Your organization can function without utilizing uninterruptible power supplies (UPS), but it is far from ideal. A UPS can protect your organization’s computer workstations and other electronic equipment from spikes in power, supply power during brief outages, and allow for time to safely power down computers in long outages. A UPS can be considered to be a type of insurance policy for computers and electronic equipment.
What Does a UPS Do?
Consider the following situation if you do not have UPSs deployed in your organization. During a heavy storm, lightning strikes and causes a black out. You don’t know how long it will last, your staff just lost all of their unsaved work, and electronic equipment may have been damaged. If your organization utilized uninterruptible power supplies throughout critical areas, your staff would have been able to save their work, safely power down their workstations, and your equipment would have been surge protected.
In addition to allowing your staff save their work and safely power down their desktops, a UPS can also defend against surges and under-voltage. However, they are not power generators that can power your organization’s workstations through extended periods of downtime. Rather, they keep your equipment powered and running while backup power generators – if you have them – start up and begin supplying power.
Considerations
If the above information about the benefits UPSs is something that your organization finds intriguing and would like to utilize them throughout its locations, then here are some considerations for selecting the ideal UPS.
Types of Uninterruptible Power Supplies
There are three main types of power supplies, differentiated by what they do and how much they cost.
- Stand-by UPS – The most basic type and lowest cost UPS, a stand-by UPS is essentially a backup battery that can supply power when it notices that the outlet has stopped providing it or isn’t providing enough. When the outlet supplies power normally, the UPS charges the battery to capacity.
- Line-Interactive UPS – A line-interactive uninterruptible power supply is a step up from a stand-by unit and features a built-in transformer that can moderate some voltage fluctuations. While a stand-by UPS is very useful for power outages, it is not designed to deal with small fluctuations in power.
- Online UPS – An online UPS is the most expensive option, but is the one that offers the most functionality. While stand-by and line-interactive UPSs are inactive while power is supplied regularly, an online UPS always modifies the power from the wall. It acts as an intermediary that is always moderating power so that it can smooth out even the tiniest of fluctuations. Online UPSs also tend to have larger batteries than the either stand-by or line-interactive UPSs. These are ideal for datacenters that employ equipment such as server systems and other costly equipment.
Wattage
Ensure that the UPS provides sufficient power for the equipment that will be connected to it. Add up the total wattage of all the equipment that will be connected to the UPS, and try to find one that provides several minutes of power for that amount of wattage. For example, if you calculate that your equipment uses a total of 500 watts, find a UPS that can supply 500 watts for several minutes and not a UPS that can supply 500 watts but only for a few seconds.
Outlets
Try to find a UPS with sufficient amount of outlets for your equipment. Be careful when looking at the numbers however, as not all outlets on an UPS may be powered by the backup battery. For example, a UPS with six outlets may only supply power from the backup battery to three outlets while the other three are just surge protected.
Operating System Compatibility
Some UPSs have the capability to alert your staff through their workstations when there is a power outage that they should save all work and safely shut down their computers.