Features: Easily access advanced features with the soft-key buttons and dot-matrix display Measure smaller objects from further away Compatibility with all standard miniconnector Type-K thermocouples Adjustable emissivity feature, including a built-in material table Capture multiple points of data for downloading and recalling later 2 levels of backlight Audible and visual alarms instantly alert you to measurements outside of your set limits Quickly identify problems with the MIN, MAX, AVG, and DIF functions Make contact thermometer measurements right away with the included Type-K thermocouple bead probe Confidently troubleshoot equipment with 1 % measurement accuracy Versatile interface with 6 languages from which to choose 2 year warranty Backlight with two levels, normal and extra bright for darker environments Trigger lock Switchable Celsius and
Fahrenheit Specifications: Infrared
temperature range: 40 C to 650 Degrees C (-40 F to 1202 Degrees F)
Infrared accuracy:: less than 0
Degrees C (32 Degrees F): +/- ( 1.0 Degree C (+/- 2.0 Degrees F) + 0.1 Degrees/1 Degree C or F); > 0
Degrees C (32 Degrees F): +/- 1 % or +/- 1.0 Degree C (+/- 2.0 Degrees F), whichever is greater
Display resolution: 0.1 Degree C / 0.1 Degrees F
Infrared spectral response: 8 um to 14 um
Infrared response time: less than 500 msec
Thermocouple Type-K input temperature range: -270 C to 1372 Degrees C (-454 F to 2501 Degrees F) Thermocouple Type-K input accuracy: -270 C to -40
Degrees C: +/-(1 DegreeC + 0.2 Degrees/1 Degree C) (-454 F to -40
Degrees F: +/- (2 Degrees F + 0.2 Degrees/1 DegreeF)) -40 C to 1372
Degrees C: +/- 1 % or 1 Degree C (-40 F to 2501
Degrees F: +/- 1 % or 2 Degrees F), whichever is greater
D: S
(distance to measurement spot size): 30:1
Laser sighting: Single-point laser less than 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size: 19 mm ( 0.75 in)
Emissivity adjustment: By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 Data storage with
Date/Time stamp: 20 points
Hi/Low alarms: Audible and two-color visual
Display: Dot matrix 98 x 96 pixels with function menus
Power: 2 AA/LR6 Batteries
Battery life (If used continuously): laser and backlight on, 12 hours; laser and backlight off, 100 hours
Operating temperature: 0 C to 50 Degrees C (32 F to 122 Degrees F)
Storage temperature: -20 C to 60 Degrees C (-40 F to 140 Degrees F) Bead thermocouple
Type-K range: -40 C to 260 Degrees C (-40 F to 500 Degrees F) Bead thermocouple
Type-K accuracy: +/- 1.1 Degrees C ( 2.0 Degrees F) from 0 C to 260 Degrees C (32 F to 500 Degrees F), typically within 1.1 Degree C ( 2.0 Degrees F) from -40 C to 0 Degrees C (-40 F to 32 Degrees F)