Battery Backup (UPS) - Showing 505 - 528 of 1080 Products
Tripp Lite Smart 750VA Sine Wave UPS Back Up, Line-Interactive 120V 600W, 1U Rackmount, ...
- Outlets: 6
- Battery Run Time: Full load runtime: 4.9 minutes (600 Watts) Half load runtime: 13.2 minutes (300 Watts)
- Output Frequency: 60 Hz
- Battery Recharge Time: Less than 4 hours from 10% to 90% (typical, full load discharge)
- Input Voltage Range: 120V AC
- Output Voltage: 120V
- Outlet Type: 5-15R
- Battery Replaceable: RBC64-1U
- Model #: SMART750RM1U
- Item #: 9B-42-111-016
- Return Policy: Manufacturer Only Return Policy
APC by Schneider Electric Smart-UPS SRT 1500VA RM 120V Network Card - 1500 VA/1350 W - ...
- Outlets: 6
- Battery Run Time: At Full Load: 4.6 Minutes At Half Load: 13.2 Minutes
- Output Frequency: 50/60 Hz +/- 3 Hz
- Battery Recharge Time: 3 Hour(s)
- Brand: APC
- Series: Smart-UPS
- International Version: 120V
- Input Voltage Range: 108 - 150V
- Model #: SRT1500RMXLA-NC
- Item #: 9B-0E6-00AX-00005
- Return Policy: Manufacturer Only Return Policy
CyberPower PR750LCD3C Smart App Sinewave UPS Systems - 750VA/750W, 100 - 125 VAC, ...
- Outlets: 6
- Battery Run Time: 1 - 30 minutes
- Output Frequency: 50/60 Hz +/- 1%
- Battery Recharge Time: 8 Hours
- Series: Smart App Sinewave
- International Version: 120V
- Input Voltage Range: 100 - 120V
- Input Frequency: 57 - 63 Hz
- Model #: PR750LCD3C
- Item #: 9SIV18MKCS7761
- Return Policy: Adorama Camera Return Policy
Tripp Lite SMART500RT1U Series 500VA 300W 120V Line-Interactive UPS - 6 NEMA 5-15R ...
- Outlets: 6
- Battery Run Time: Full Load Runtime (min.): 3 min. (300w) Half Load Runtime (min.): 14 min. (150w)
- Output Frequency: 60 Hz
- Battery Recharge Time: Less than 12 hours to 90%
- International Version: 120V
- Input Frequency: 60 Hz +/- 3 Hz
- Input Connection: 5-15P
- Output Voltage: 120Vac +/- 5%
- Model #: SMART500RT1U
- Item #: 9B-42-111-015
- Return Policy: Manufacturer Only Return Policy
CyberPower OL3KRTHD Smart App Online UPS Systems, 3000VA/2700W, 100 - 125 VAC, ...
- Outlets: 7
- Battery Run Time: 8.5 minutes / 2.7 minutes Runtime (half/full)
- Battery Recharge Time: 4 Hours (0% to 90% charged)
- Brand: CyberPower
- International Version: 120V
- Input Voltage Range: 100 - 125V
- Input Frequency: 40 - 70 Hz
- Input Connection: NEMA L5-30P
- Model #: OL3KRTHD
- Item #: 9B-42-102-506
- Return Policy: Manufacturer Only Return Policy
APC Smart-UPS SRT 1000VA/900W Rack-Mount 120V 2U 6x15R 480J UPS ...
- Outlets: 6
- Battery Run Time: At Full Load: 10.5 Minutes At Half Load: 25.4 Minutes
- Output Frequency: 50/60 Hz +/- 3 Hz
- Battery Recharge Time: 3 Hour(s)
- Brand: APC
- Series: Smart-UPS
- International Version: 120V
- Input Voltage Range: 80 - 150V
- Model #: SRT1000RMXLA-NC
- Item #: 9SIV04ZKK43572
- Return Policy: IPC Store Return Policy
CyberPower AVRG900LCD Intelligent LCD UPS Systems - 900VA/480W, 120 VAC, NEMA ...
- Outlets: 12
- Battery Run Time: 2 min at Full Load / 10 min at Half Load
- Battery Recharge Time: 8 Hours
- Brand: CyberPower
- Input Voltage Range: 90 VAC - 148 VAC
- Input Frequency: 57 - 63 Hz
- Input Connection: NEMA 5-15P
- VA Rating: 900 VA
- Model #: AVRG900LCD
- Item #: 9B-42-102-257
- Return Policy: Manufacturer Only Return Policy
CyberPower PR2200LCDSL Smart App Sinewave UPS Systems - 2070VA/1980W, 120 VAC, ...
- Outlets: 7
- Battery Run Time: Runtime at Half Load (min): 10 Runtime at Full Load (min): 3
- Output Frequency: 60Hz +/- 1%
- Battery Recharge Time: 8 Hours
- Brand: CyberPower
- Series: Smart App Sinewave
- International Version: 120V
- Input Voltage Range: 75Vac - 154Vac +/- 3Vac
- Model #: PR2200LCDSL
- Item #: 9B-42-102-221
- Return Policy: Manufacturer Only Return Policy
EATON 9SX1500 1500 VA 1350W 6 Outlets UPS
- Outlets: 6
- Battery Run Time: 1350W: 6 min
- Output Frequency: 50/60 Hz
- Input Frequency: 60 Hz: 50-70 Hz, 50 Hz: 40-60 Hz
- Input Connection: 5-15P
- Output Voltage: 120V default (100/110/120/125V)
- Outlet Type: NEMA 5-15R
- Battery Replaceable: Hot-swappable internal batteries and extended battery modules (EBMs)
- Model #: 9SX1500
- Item #: 9SIV0098GX2177
- Return Policy: Antonline.com Return Policy
Eaton 5PX1500RTG2 5PX G2 1440VA 1440W 120V Line-Interactive UPS - 8 NEMA 5-15R ...
- Outlets: 8
- Battery Run Time: Runtime Full Load (min.) 5 min. (1440W) Runtime Half Load (min.) 15 min. (720W)
- Brand: EATON
- Input Connection: NEMA 5-15P
- VA Rating: 1440 VA
- Watts: 1440 Watts
- Output Voltage: 120V
- Outlet Type: 8 x NEMA 5-15R
- Model #: 5PX1500RTG2
- Item #: 9SIV009K2J8691
- Return Policy: Antonline.com Return Policy
APC Smart-UPS Line Interactive 2200VA Lithium-ion Rackmount 2U 120V 2x NEMA 5-20R+6x ...
- Brand: APC
- Parts: 5 Year
- Model #: SMTL2200RM2UCNC
- Item #: 9SIV009K2P3199
- Return Policy: Antonline.com Return Policy
Tripp Lite Rbc36h Ups Battery Pack
- Weight: 2.25
- Model #: RBC36H
- Item #: 9SIV009E8A5882
- Return Policy: Antonline.com Return Policy
Eaton 5PX G2 1950VA 1950W 120V Line-Interactive 6-Outlet UPS 5PX2000RTNG2
- Parts: 3 Year
- Model #: 5PX2000RTNG2
- Item #: 9SIV009K2J8690
- Return Policy: Antonline.com Return Policy
1500 VA 865 W External Battery Pack for Back-UPS RS/XS 1500VA
- Battery Run Time: At full load (865W): The runtime can be extended from around 3 minutes At half load (432.5W): The runtime can be extended from around 11 minutes
- VA Rating: 1500 VA
- Watts: 865 W
- Battery Type: Lead Acid Battery
- Model #: BR24BPG
- Item #: 9SIV1DSKAF0712
- Return Policy: NothingButSavings Return Policy
EATON 5SC750G 750 VA 525 W 6 Outlets UPS
- Outlets: 6
- Input Voltage Range: 184 - 276 Vac
- Input Frequency: 50/60 Hz
- Input Connection: IEC-320-C14
- Output Voltage: 230V
- Outlet Type: IEC-320-C13
- Interface Port: RS-232 (RJ45) port; USB port as standard (HID)
- Management Software: YES
- Model #: 5SC750G
- Item #: 9SIV1DSKAV8388
- Return Policy: NothingButSavings Return Policy
5P 750VA SHORT RACK 2U
- Outlets: 10
- Battery Run Time: Half Load: 12 Minutes Full Load: 5 Minutes
- Output Frequency: 50/60 Hz +/- 0.1%
- International Version: 120V
- Input Voltage Range: 89 - 151 V
- Input Frequency: 50/60 Hz
- Input Connection: NEMA 5-15P
- Output Voltage: 120V
- Model #: 5P750RC
- Item #: 9SIV0095B57768
- Return Policy: Antonline.com Return Policy
Eaton Tripp Lite series 48V Extended Battery Module (EBM) for 750VA, 1000VA and 1500VA ...
- Parts: 1 Year
- Model #: BP48VRM2U
- Item #: 9SIV009K1V2374
- Return Policy: Antonline.com Return Policy
BTI APCRBCV210-BTI 12V 1-CELL LEAD ACID UPS BATTERY FOR APCRBCV210 RBC210 - ...
- Model #: APCRBCV210-BTI
- Item #: 9SIV009KS67803
- Return Policy: Antonline.com Return Policy
Vertiv Liebert POD PD5 - (8) IEC|UPS Maintenance Bypass for GXT5 5-6KVA HV PD5-201
- Model #: PD5-201
- Item #: 9SIV009KW02585
- Return Policy: Antonline.com Return Policy
Eaton Electrical 5S1000LCD External UPS
- Outlet Type: Battery
- Battery Type: Battery
- Weight: 23.75
- Model #: 3571332
- Item #: 9SIV04ZKK43092
- Return Policy: IPC Store Return Policy
APC BE650G1-LM 650 VA 390 Watts 8 Outlets UPS
- Outlets: 8
- Battery Recharge Time: 24 hours
- International Version: 120V
- Input Frequency: 50/60 Hz
- Input Connection: NEMA 5-15P
- Output Voltage: 120V
- Outlet Type: (4) NEMA 5-15R (Battery Backup) (4) NEMA 5-15R (Surge Protection)
- Interface Port: USB
- Model #: BE650G1-LM
- Item #: 9SIV1DSKAD9054
- Return Policy: NothingButSavings Return Policy
Tripp Lite SmartPro SMART1500RM2UL 1500VA Rack-mountable UPS Lithium Battery ...
- Outlets: 4 x NEMA 5-15/20R 4 x NEMA 5-15R
- Brand: TRIPP LITE
- Output Voltage: 110 V AC 115 V AC 120 V AC
- Battery Type: Lithium Ion
- Parts: 5 Year
- Model #: SMART1500RM2UL
- Item #: 9SIV009K145848
- Return Policy: Antonline.com Return Policy
APC SMT1500RM2UCNC Smart-UPS, Line Interactive, 1500VA, Rackmount 2U, 120V, 6x ...
- Outlets: 6
- Output Frequency: 50/60 Hz +/- 3 Hz sync to mains
- Battery Recharge Time: <3 Hours
- Series: Smart-UPS
- Part Number: SMT1500RM2UCNC
- Input Voltage Range: 110 V 125 V
- Input Frequency: 50/60 Hz +/- 3 Hz auto-sensing
- Input Connection: NEMA 5-15P
- Model #: SMT1500RM2UCNC
- Item #: 9SIV1DSKAV3339
- Return Policy: NothingButSavings Return Policy
Liebert GXT5 3kVA 208V Double Conversion Rack/Tower UPS
- Outlets: 2 x NEMA L6-15R 2 x NEMA L6-20R
- Output Voltage: 208 V AC
- Parts: 3 Year
- Model #: GXT5-3KL620RT2UXL
- Item #: 9SIV009GUG6699
- Return Policy: Antonline.com Return Policy
What is an Uninterruptible Power Supply?
Your organization can function without utilizing uninterruptible power supplies (UPS), but it is far from ideal. A UPS can protect your organization’s computer workstations and other electronic equipment from spikes in power, supply power during brief outages, and allow for time to safely power down computers in long outages. A UPS can be considered to be a type of insurance policy for computers and electronic equipment.
What Does a UPS Do?
Consider the following situation if you do not have UPSs deployed in your organization. During a heavy storm, lightning strikes and causes a black out. You don’t know how long it will last, your staff just lost all of their unsaved work, and electronic equipment may have been damaged. If your organization utilized uninterruptible power supplies throughout critical areas, your staff would have been able to save their work, safely power down their workstations, and your equipment would have been surge protected.
In addition to allowing your staff save their work and safely power down their desktops, a UPS can also defend against surges and under-voltage. However, they are not power generators that can power your organization’s workstations through extended periods of downtime. Rather, they keep your equipment powered and running while backup power generators – if you have them – start up and begin supplying power.
Considerations
If the above information about the benefits UPSs is something that your organization finds intriguing and would like to utilize them throughout its locations, then here are some considerations for selecting the ideal UPS.
Types of Uninterruptible Power Supplies
There are three main types of power supplies, differentiated by what they do and how much they cost.
- Stand-by UPS – The most basic type and lowest cost UPS, a stand-by UPS is essentially a backup battery that can supply power when it notices that the outlet has stopped providing it or isn’t providing enough. When the outlet supplies power normally, the UPS charges the battery to capacity.
- Line-Interactive UPS – A line-interactive uninterruptible power supply is a step up from a stand-by unit and features a built-in transformer that can moderate some voltage fluctuations. While a stand-by UPS is very useful for power outages, it is not designed to deal with small fluctuations in power.
- Online UPS – An online UPS is the most expensive option, but is the one that offers the most functionality. While stand-by and line-interactive UPSs are inactive while power is supplied regularly, an online UPS always modifies the power from the wall. It acts as an intermediary that is always moderating power so that it can smooth out even the tiniest of fluctuations. Online UPSs also tend to have larger batteries than the either stand-by or line-interactive UPSs. These are ideal for datacenters that employ equipment such as server systems and other costly equipment.
Wattage
Ensure that the UPS provides sufficient power for the equipment that will be connected to it. Add up the total wattage of all the equipment that will be connected to the UPS, and try to find one that provides several minutes of power for that amount of wattage. For example, if you calculate that your equipment uses a total of 500 watts, find a UPS that can supply 500 watts for several minutes and not a UPS that can supply 500 watts but only for a few seconds.
Outlets
Try to find a UPS with sufficient amount of outlets for your equipment. Be careful when looking at the numbers however, as not all outlets on an UPS may be powered by the backup battery. For example, a UPS with six outlets may only supply power from the backup battery to three outlets while the other three are just surge protected.
Operating System Compatibility
Some UPSs have the capability to alert your staff through their workstations when there is a power outage that they should save all work and safely shut down their computers.